What's Included

Full Scope of Work

Pan-India Multi-Outlet 24/7 Facility AMC
Pan-India Multi-Outlet 24/7 Facility AMC: Contractually committed preventative maintenance routines covering hood degreasing, blower balancing, refrigerant top-ups, and emergency breakdown resolution within a <2-hour SLA. Designed specifically for multi-brand cloud kitchens, restaurant chains, and retail franchises with centralized ticketing and guaranteed SLA uptime.
Comprehensive vs. Non-Comprehensive AMC
Customized Annual Maintenance Contracts tailored to institutional and high-stakes defense/industrial operations. Comprehensive AMC includes all routine consumables, OEM repair kits, and major breakdown replacement parts. Non-Comprehensive AMC delivers full-scope technical asset maintenance, scheduled overhauls, emergency troubleshooting, and technical personnel coverageβ€”proven by our 4-year continuous non-comprehensive asset maintenance contract for Zen Technologies' high-altitude Ladakh facility maintaining heavy military simulation machinery and industrial HVAC systems with zero downtime.
24/7 Resident Engineers & Multi-Skilled Technicians
Deputation of certified shift electrical engineers, licensed wiremen, HVAC chiller operators, and plumbing technicians directly at your plant. Shift handover protocols, computerized maintenance management system (CMMS) ticketing, automated daily energy logs, and round-the-clock supervisor escalation across Punjab, Mohali, Ludhiana, and Baddi.
Planned Preventive Maintenance (PPM) Matrix
Exhaustive daily, weekly, monthly, quarterly, and annual maintenance schedules for 11kV/33kV substations, transformers, PCC/MCC switchboards, APFC capacitor banks, chillers, AHUs, fire hydrants, and diesel generators. Eliminates unexpected catastrophic machine halts through scheduled pre-failure interventions.
Live Thermography Scans & Electrical Audits
Scheduled non-destructive infrared thermographic imaging of live busbars, MCCB terminals, contactors, and cable terminations per IS 16168. Detects high-resistance loose lugs, phase imbalances, and localized thermal hot-spots before electrical fires or busbar flashovers can erupt.
APFC Maintenance & 0.99 Power Factor Guarantee
Routine capacitance testing, detuned reactor harmonic inspection, and microprocessor APFC relay tuning. We guarantee an active operational power factor between 0.98 and 0.99+, totally protecting your facility from massive low-power-factor financial penalties on monthly PSPCL / State electricity bills while claiming maximum available power factor rebates.
Chiller Descaling, AHU Sanitization & HVAC Overhauls
Periodic chemical and mechanical tube cleaning of shell-and-tube condenser barrels, cooling tower basin descaling, biological biocidal dosing, dynamic fan balancing, and double-skin AHU coil pressure washing. Restores nominal Delta-T and reduces chiller kilowatt consumption per ton of refrigeration (kW/TR).
Rapid Breakdown SLA (<2 to 4 Hours Response)
Contractually committed Mean Time to Respond (MTTR) with dedicated emergency mobile response squads stationed across Patiala, Mohali, Chandigarh, Ludhiana, Mandi Gobindgarh, and Baddi. Fully equipped mobile repair vans stocked with vacuum circuit breaker spares, contactors, multi-gas refrigerant cylinders, and testing instruments.
Heavy Machinery Asset Preservation & Spares
Dedicated asset tagging, OEM spare inventory management, vibration spectrum analysis on multi-stage pumps and drive motors, bearing greasing regimens, and life-extension engineering for critical manufacturing equipment, cold chain compressors, and heavy CNC systems.

Download Official Engineering Checklist

Free 1-click printable technical protocol and statutory compliance guide curated by our senior engineers for plant heads, facility directors, and consultants.

πŸ“„ Document Ref: RSE-DOC-PPM-AMC-26
Comprehensive MEP Planned Preventive Maintenance (PPM) Matrix
Standard operating procedures, infrared thermography routines, APFC power factor management, and SLA protocols for critical commercial & industrial assets.
  • APFC capacitor bank maintenance targeting power factor ≥0.98–0.99 to eliminate PSPCL surcharges
  • Infrared thermographic scanning (IS 16168) with ΔT > 10°C phase comparison investigation trigger
  • DG Set acoustic enclosure attenuation (≤75 dBA @ 1m) and dual battery bank testing
  • Incident response MTTR <4 hours SLA for critical power and HVAC infrastructure
πŸ“₯ Open & Download Printable PDF Guide →

Long-Term Maintenance Contracts: Zero-Downtime Performance

Real performance records from multi-year non-comprehensive and comprehensive asset maintenance contracts executed by RS Electricals & HVAC Solutions.

πŸ›‘οΈ Defence & Industrial Simulation πŸ“ Ladakh High-Altitude Station ⭐ 4 Years Straight

Zen Technologies β€” 4-Year Heavy Machinery Asset AMC

RS Electricals provided complete non-comprehensive asset maintenance throughout 4 consecutive years straight with zero downtime issues and rapid emergency response for Zen Technologies' remote Ladakh facility. Our scope covered heavy machinery, simulation drives, high-voltage panels, and specialized sub-zero HVAC systems under extreme Himalayan high-altitude stress.

  • Zero unplanned operational outages across 4 consecutive years
  • Sub-zero cold climate HVAC defrost tuning & heating coil management
  • Rapid response SLA protocol with fast diagnosis & technical intervention
  • Periodic Megger insulation diagnostics & motor contactor overhauls
βœ“ 4-Year Non-Comprehensive AMC β€’ 100% Technical Reliability
πŸ’‡ Commercial Luxury Retail πŸ“ Patiala β€’ Panchkula β€’ Mohali ⭐ 5 Years Active

Hair Masters Luxury Salons β€” 5-Year Luxury Asset AMC

Complete preventive maintenance management covering multi-tier HVAC assets across flagship salon towers in Patiala, Panchkula, and Mohali for over 5 straight years. Our engineering AMC protocol preserves luxury ambiance, guest comfort, and staff productivity without disruption.

  • 5 straight years of zero operational disruption during peak salon footfalls
  • Multi-stage indoor unit filter cleaning & continuous chemical fume mitigation
  • Whisper-quiet acoustic balancing (<38 dBA) preserving relaxation
  • Refrigerant charge monitoring, coil descaling & compressor lifecycle extension
βœ“ 5-Year Continuous AMC β€’ Customer Comfort & Asset Protection
Our Engineering Approach

Design β†’ Install β†’ Maintain β†’ Optimize

AMC isn't a checkbox service call schedule β€” it's built around your specific equipment inventory, criticality ranking, and SLA needs, with predictive maintenance identifying issues before they become breakdowns.

Deployed In

Industries Using This Service

Related

Other Services

Get a Facility Management & AMC Assessment
Technical assessment, cost optimization roadmap, and execution plan tailored to your facility.
Request Assessment Call +91 62399-13625

Frequently Asked Questions

Authoritative technical specifications and statutory guidelines verified by RS Electricals & HVAC Solutions engineering teams.

An RS Comprehensive or Non-Comprehensive HVAC AMC includes scheduled quarterly planned preventative maintenance (PPM), monthly filter washing and chemical coil cleaning, compressor motor insulation testing, refrigerant leak detection, chilled water pump alignment, cooling tower dosing checks, VFD diagnostic scans, and priority 24/7 breakdown callouts.

Look for an engineering-led contractor with: (1) direct multi-brand OEM technical experience (chillers, VRF, AHUs), (2) in-house certified technicians and calibrated diagnostic tooling (FLIR thermography, anemometers, manifold gauges), (3) proven statutory compliance (ESIC/EPF/GST), and (4) guaranteed emergency SLA response times under 2 hours.

Yes. We manage annual maintenance contracts for corporate headquarters, IT park campuses, and industrial production plants across Punjab, Chandigarh, Baddi, and Delhi NCR, maintaining optimal COP and zero unplanned operational downtime.

Under our Comprehensive AMC (CAMC), all emergency breakdown service visits and replacement of worn components (contactor coils, capacitors, bearings, thermostats, refrigerant top-ups) are fully covered. Under Non-Comprehensive AMC, labor and scheduled PPM are covered, while replacement spares are billed transparently at pre-negotiated rate schedules.

Commercial equipment requires a multi-tier routine: air filters cleaned every 15-30 days; electrical connections, contactors, and fan belts inspected monthly; compressor oil acidity, chiller refrigerant charge, and cooling towers audited quarterly; and comprehensive descaling, tube eddy-current testing, and motor rewinding audits conducted annually.

Preventive maintenance (PPM) follows pre-scheduled engineering protocols to inspect, lubricate, clean, and adjust equipment before failure occurs, extending asset lifecycle by 30-40%. Breakdown maintenance is reactive emergency repair following an unexpected failure, which incurs production stoppages, emergency rental costs, and accelerated component wear.

Yes. RS provides centralized multi-site AMC agreements for corporate chains, multi-branch hospitals, and industrial groups with single-point administrative billing, standardized service level agreements (SLAs), and digital service logs.

We need an asset inventory list stating: equipment make, model, capacity (TR/CFM), age, refrigerant type, location, operational hours per day (8h, 16h, or 24/7 continuous), and the maintenance history or recent service logs of the machines.

Absolutely. Consistent engineering maintenance prevents up to 85% of sudden compressor burnouts, motor bearing seizures, and refrigerant charge loss, while reducing facility energy consumption by 15% to 25% through clean heat-exchange surfaces.

A professional provider must submit: (1) sign-off service job cards after each visit, (2) monthly equipment health check logs (suction/discharge pressures, amp draws, temperatures), (3) quarterly PPM completion reports, and (4) annual thermodynamic efficiency audit summaries.

Before signing an AMC, RS conducts a thorough site health assessment: measuring airflow CFM, motor current draws, compressor vibration, coil fin conditions, refrigerant pressures, and duct leakage to document baseline operational integrity.

Integrated facility management (IFM) by RS encompasses 24/7 technical operations and maintenance (O&M) of electrical substations, central chiller plants, plumbing and water treatment systems, fire fighting networks, building automation (BMS), and DG power backup.

Yes. We deploy full-time onsite shift engineers, multi-skilled technicians, and facility managers backed by automated work order management systems (CMMS), strict PPM calendars, and KPI/SLA accountability for zero downtime.

Yes. Comprehensive technical FM covers daily HVAC temperature logs, chiller efficiency tracking, electrical switchboard inspections, APFC power factor monitoring, and planned preventative maintenance of all MEP infrastructure.

Yes. We configure digitized PPM calendars with equipment asset tagging, barcoded maintenance checklists, and automated alert workflows ensuring 100% compliance with OEM maintenance recommendations and statutory safety guidelines.

An AMC is typically an equipment-specific periodic maintenance contract with scheduled visits (e.g., quarterly chiller servicing). Facility Management is a comprehensive, continuous service with dedicated onsite technical staff managing all interconnected building utilities.

Yes. We support corporate real estate portfolios, retail chains, and industrial enterprises across multiple locations in Punjab, Haryana, and Delhi NCR with standardized operational SLAs and centralized monthly management reporting.

We require the site equipment register, single-line electrical schematics, HVAC equipment schedule, operational hours, existing utility utility consumption baselines, and historical maintenance logs.

Yes. Continuous technical oversight and adherence to proactive PPM schedules reduce major plant failures by up to 90%, eliminate premature component degradation, and lower building lifecycle operational expenditure (OPEX) by 20%.

A professional FM partner delivers daily utility consumption logs, monthly PPM completion scorecards, mean time between failures (MTBF) and mean time to repair (MTTR) reports, and quarterly energy conservation audit recommendations.

RS executes a structured 30-day transition protocol: asset condition audit, tagging and barcoding, standard operating procedure (SOP) benchmarking, tool and safety gear mobilization, and shadow operations with the existing team to ensure zero operational disruption.

When comparing AMC proposals, evaluate: (1) Total number of mandatory quarterly PPM visits versus emergency breakdown visits, (2) Guaranteed SLA emergency response time, (3) Comprehensive inclusions (gas top-up, contactors, motors, oil) versus exclusions, and (4) Direct technical capability of the contractor's resident workforce.