Service — Intelligence & Security

Lighting Design
& Controls

Architectural, industrial, and facade lighting paired with DALI/DMX controls — engineered for both aesthetics and energy efficiency.

Request Lighting Design & Controls Assessment
What's Included

Full Scope of Work

Architectural & Facade Lighting
Architectural LED lighting enhancing building facades, monuments, and corporate headquarters with dynamic color rendering. Custom beam angle selection, IP67 weatherproof luminaires, and DMX512 programming for synchronized night-time aesthetics.
Industrial & Warehouse Lighting
High-bay and low-bay industrial LED fixtures engineered for high ceilings, manufacturing floors, and logistics hubs. Dialux photometric calculations ensuring uniform lux distribution (>300 lux) and low glare (UGR < 22) per IS 3646.
Landscape & Street Lighting
Solar and grid-powered LED streetlights, bollards, and landscape illumination for industrial parks and townships. Smart optical lenses with Type II/III distribution minimizing light pollution and dark spots along roads and pathways.
Sports Lighting
High-intensity floodlighting for stadiums, indoor sports complexes, and corporate recreational grounds. Flicker-free illumination suitable for HDTV broadcast with high Color Rendering Index (CRI > 80) and uniform lux levels.
Smart & Emergency Lighting
Intelligent lighting control systems with occupancy sensing, daylight harvesting, and NBC-compliant emergency escape lights. Self-contained battery backup systems providing mandatory escape illumination for a minimum of 90 minutes during power cuts.
DALI & DMX Control Systems
Digital Addressable Lighting Interface (DALI-2) and DMX controllers providing individual fixture addressing and dimming. Seamless integration with central BMS, enabling customized lighting scenes, scheduled dimming, and individual lamp failure telemetry.
Lighting Energy Audits
Comprehensive surveys measuring ambient lux levels, lamp wattages, and power quality across existing commercial facilities. Turnkey LED retrofit roadmaps delivering 50–65% reductions in lighting electricity bills with rapid payback under 18 months.

Download Official Engineering Checklist

Free 1-click printable technical protocol and statutory compliance guide curated by our senior engineers for plant heads, facility directors, and consultants.

📄 Document Ref: RSE-DOC-LGT-LUX-26
Architectural & Industrial High-Bay Lighting Lux Level Verification Checklist
Illuminance mapping, Unified Glare Rating (UGR), DALI-2 automation, and emergency egress lighting compliance for factories, warehouses, and offices.
  • Calibrated Lux mapping: Factory floors 200–300 Lux; Assembly 500–750 Lux; Uniformity ≥0.60
  • Unified Glare Rating UGR < 19 for workspaces evaluated based on room geometry and observer position
  • DALI-2 addressable dimming, daylight harvesting photocells & motion sensor delay tuning
  • Emergency escape lighting: Minimum 10 Lux along escape routes with ≥90-minute battery autonomy
📥 Open & Download Printable PDF Guide →
Our Engineering Approach

Design → Install → Maintain → Optimize

Lighting layouts are designed against actual lux-level requirements per space type, then paired with DALI/DMX controls so lighting responds to occupancy and daylight — cutting energy use without compromising the visual design intent.

Deployed In

Industries Using This Service

Related

Other Services

Frequently Asked Questions

Authoritative technical specifications and statutory guidelines verified by RS Electricals & HVAC Solutions engineering teams.

Yes. Deploying DALI-2 smart lighting controls, occupancy motion sensors, and daylight harvesting photocells in commercial and industrial facilities reduces lighting energy consumption by 40% to 65% while extending LED luminaire operating life.

Yes. Modern BMS platforms communicate via open protocols (BACnet IP, Modbus TCP) to integrate HVAC performance data directly with digital power meters, enabling real-time calculation of facility Power Usage Effectiveness (PUE) and automated demand-limiting routines.

An electrical safety audit should be conducted: (1) annually as required under CEA Safety Regulations 2010, (2) before statutory CEIG / insurance renewal, (3) following unexplained breaker trips, or (4) prior to major facility expansions or load additions.

Our engineers record real-time voltage, current, active power (kW), apparent power (kVA), power factor, and unbalance across all phases using Class-A power quality analyzers to calculate true maximum demand, spare transformer capacity, and feeder utilization.

A turnkey commercial building MEP package integrates: (1) High and low voltage electrical power distribution (substation, transformers, panels, diesel generators, cabling, lighting), (2) Central HVAC (chillers, VRV/VRF, AHUs, ducting, ventilation), (3) Fire fighting and life safety (hydrants, sprinklers, fire pumps, alarm, PA voice evac), (4) Public health engineering/plumbing (water supply, drainage, STP), and (5) Building Management Systems (BMS / ELV security / CCTV).

Get a Lighting Design & Controls Assessment
Technical assessment, cost optimization roadmap, and execution plan tailored to your facility.
Request Assessment Call +91 62399-13625